China Electrical Power Transformer manufacturer

MNS LV Switchgear Panel Industrial Electrical Power Transmission Use

Product Details:
Place of Origin: China
Brand Name: HENGFENGYOU
Certification: ISO IEC CB COC KEMA SNI SABS CCC
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: 200-20000/piece
Packaging Details: wooden case
Delivery Time: 30 days
Payment Terms: LC T/T
Supply Ability: 5000 piece/year
Contact Now

Detail Information

Model Number: MNS Max Current: UP To 5000A
Frequency: 50Hz Keyword: MNS Drawable Cabinet
Certificate: ISO9001 OEM: Provided
Rated Voltage: 380V/660V Standard: IEC439-1 GB7251.1 JB/T9961
Product Name: Upto 5000A Drawable/Drawout Low Voltage Application: Electric Power Transmission
Warranty: 1 Year
High Light:

electrical switch cabinet

,

switchgear control panel

Product Description

MNS LV Electric Power Distribution Switchgear
 
 
Product Description

MNS LV withdrawable switchgear (hereinafter referred to as device) is manufactured by standard module through consulting MNS series low voltage switch cabinet of Switzerland ABB Company and synthetically improved. The device is applicable to the system with AC 50Hz, rated working voltage 660V and below, used as a control device for various power generation, transmission, distribution, power transfer, and power consumption device. It is widely used in low voltage distribution systems of the various mining enterprise, tall buildings, and hotels, municipal construction, etc. Besides the general land
use, after special disposal, it also can be used for marine petrol drill taken platform and nuclear power station. The device accords with international standard IEC439-1 and national standard GB7251.1.

MNS LV Switchgear Panel Industrial Electrical Power Transmission Use 0
Work Environment

1. Ambient air temperature: -5℃+40℃and the average temperature should not exceed +35℃ in 24h.
2. Air condition: With clean air. Relative humidity should not exceed 50% at +40℃. The higher relative humidity is allowed at a lower temperature. Ex. 90% at +20℃. But in view of the temperature change, it is possible that
moderate dews will produce casually.
3. Altitude above sea level should not exceed 2000M.
4. The device is suitable for transportation and store with the following temperature:-25℃ ~+55℃, in a short time (within 24h) it reaches +70℃. Under the limiting temperature, the device should not suffer damage that
can[1]t recover, and it can works normally under normal conditions.
5. If the above operating conditions not meet the user’s demand. Consult with manufactory.
6. Technical agreement should be signed additionally if the device is used for marine petrol drill taken
platform and nuclear power station

 

Item Data
Rated voltage to 660V
Ratd voltage impacte indurance 8KV
Rated frequency 50/60hz
Grounding system TT,IT, TN-S,TN-C-S
Ratd voltage of auxiliary circuit AC380,220v/ DC220v
Maximum coil in and out broken circuit 6300A
Pollution degree 3
Rated current 6300A
Horizontal busbar rated current 4000A
Vertical busbar rated current 2000A,1000A
Horizontal busbar ratd shorttime withstand current 50/80KA
Horizontal busbar rated peak value withstand current 105/176KA
Vertical busbar rated short time withstand current 50KA
Vertical busbar rated peak value withstand current 105KA

MNS LV Switchgear Panel Industrial Electrical Power Transmission Use 1
MNS LV Switchgear Panel Industrial Electrical Power Transmission Use 2 

Get in touch with us