China Electrical Power Transformer manufacturer

S11 Series Fully Sealed Type Transformer High Efficiency Oil Immersed Cooper Winding Material

Product Details:
Place of Origin: China
Brand Name: HENGFENGYOU
Certification: ISO IEC CB COC KEMA SNI SABS CCC
Model Number: S9.11,13
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: 200-200000/piece
Packaging Details: wood
Delivery Time: 15 DAYS
Payment Terms: T/T
Supply Ability: 5000 pieces/year
Contact Now

Detail Information

Usage: Power,Distribution Transformer Phase: Three
Frequency: 50/60Hz Type: Oil Immersed,Oil Type,oil Immersed Current Transformer 132kv
Product Name: 33/10 Kv 50/60Hz 5000Kva Oil Immersed Power Distribution Transformer Material: Copper+alumnium
Output Voltage: 15kv 10 Kv 0.4/0.69kv Winding Material: Cooper
High Light:

industrial power transformer

,

power distribution transformer

Product Description

S11 Series Fully Sealed Type Transformer High Efficiency Oil Immersed Cooper Winding Material

 

11KV oil immersed transformer

Introduction to Products

The performances of model S9-M, S10-M, S11-M 10kv series full-sealed oil-immersed distribution transformes conform to Standards IEC. Its core is made of quality cold-rolled silicon sheet and is of a full-miter non-puncture structure and its oil is made of quality oxygen-free copper.

It adopts radiator oil tank of corrugated shteet type or expansion type. As it doesn't need oil conservator, the height of transformer is reduced, and as the transformer oil doesn't contract with air, the oil ageing is retarded, thus prolonging the service life of transformer. The no-load loss of Model S10-M is 20% lower than that of Model S9-M, and S11-M is 30% lower than S9-M.

 

· Service conditions

1. The maximum ambient air temperature shall not exceed 40 ℃, and the minimum shall not below - 25 ℃;

2. The altitude shall not exceed 1000m. If special customized transformers and low-voltage components are used, the altitude can reach 4000m;

3. The vertical inclination is no more than 5°, and no violent vibration and impact;

4. The air humidity is not more than 90% (+ 25 ℃);

5. No gas and conductive dust that will seriously affect the insulation of transformer, no explosion hazard and corrosion of electrical components;

6. Outdoor wind speed shall not exceed 35m / s.

7.If service conditions beyond the above, specially customized product is available.

 

 

· Structural features

1. The transformer core is made of folded import high-quality cold-rolled silicon steel sheet, which greatly reduces no-load loss and no-load current. The core is bound to ensure the compactness and reduce noise.

2. The high and low voltage winding is made of oxygen-free copper,. The low voltage winding of 500KVA and below is of double-layer barrel structure, and of 630kVA and above is of double helix or four helix structure. The high-voltage winding normally adopts multi-layer barrels structure.

3. Dyn11 method is applied to the transformer connection to reduce the influence of harmonics on the power grid and improve the quality of power supply.

4. The transformer is a fully-sealed structure, which can extend its service life, free of core -lifting and maintenance.

5. The measured noise value is lower than the standard. After normal transportation, this series of transformers can be installed with relevant parts and components without core- lifting inspection, and can be put into operation after passing the acceptance test.

 

Note: Due to continuous product improvement, the dimensions provided in this sample are for reference only. If necessary, our company can design and produce according to user requirements. Please contact the company in time.

 

Main Technical Parameters for 10KV level S9-M/S10-M/S11- M Series three-phase full-sealed non-excitaiton-tap-changing distribbution transformer
Rated
Power
(kva)
High
Voltage
(kv)
H.V.Tap
range
Low
Voltage
(kv)
Connection
symbol
Short
Circuit
Impendence
(%)
No-load loss(W) On-load loss(W) No load
current
(%)
S9 S10 S11 S9 S10 S11
30 6
6.3
10
10.5
11
±5%
±2x2.5%
0.4 Dyn11
Yyn0
4 130 110 100 600 600 600 2.1
50 170 150 130 870 870 870 2
63 200 180 150 1040 1040 1040 1.9
80 250 200 180 1250 1250 1250 1.8
100 290 230 200 1500 1500 1500 1.6
125 340 270 240 1800 1800 1800 1.5
160 400 310 280 2200 2200 2200 1.4
200 480 380 340 2600 2600 2600 1.2
250 560 460 400 3050 3050 3050 1.2
315 670 540 480 3650 3650 3650 1.1
400 800 650 570 4300 4300 4300 1
500 960 780 680 5150 5150 5150 1
630 4.5 1200 920 810 6200 6200 6200 0.9
800 1400 1120 980 7500 7500 7500 0.8
1000 1700 1320 1150 10300 10300 10300 0.7
1250 1950 1560 1360 12000 12000 12000 0.6
1600 2400 1880 1640 14500 14500 14500 0.6
2000 5 2830 2270 1940 17140 17140 17140 0.6
2500 3350 2690 2300 20260 20260 20260 0.5


· Order instructions:

1. The customer needs provide main parameters of the transformer (input and output voltage, capacity, loss, etc.)

2. Other customer requirements

 

Workshop pictures:

 

 

S11 Series Fully Sealed Type Transformer High Efficiency Oil Immersed Cooper Winding Material 0

 

 

 

Package Details:

 

 

S11 Series Fully Sealed Type Transformer High Efficiency Oil Immersed Cooper Winding Material 1

 

 

Get in touch with us

Enter Your Message

You Might Be Into These