Product Details:
|
|
Place of Origin: | China |
---|---|
Brand Name: | HENGFENGYOU |
Certification: | ISO IEC CB COC KEMA SNI SABS CCC |
Model Number: | customization |
Payment & Shipping Terms:
|
|
Minimum Order Quantity: | 1 |
Price: | 2000-200000/piece |
Packaging Details: | Standard wooden boxes for outer packing |
Delivery Time: | 30 days |
Payment Terms: | LC T/T |
Supply Ability: | 5000 pieces/year |
Detail Information |
|||
Product Name: | Box Type Fixed Metal Closed Switchgear / High Voltage Switchgear,Substation,outdoor Prefabricated Compact 11kv Substation,switchgear Outdoor Pre Installed Type Transformer Substation | Type: | Distribution Box Electrical Boxes,Box Type Prefabricated Substation |
---|---|---|---|
Rated Voltage: | 10KV,40.5kV,13.2KV,10KV~40KV,6kv To 35kV | Frequency: | 50/60Hz |
Phase: | Three | Color: | Customer Request |
Rated Capacity: | 30-3000kva | ||
Highlight: | power distribution substation,electrical distribution substation |
Product Description
China Intelligent Pre-Assembled Power Distribution Wind Energy Electrical Transformers Box Substation
Product description
YB typed pre-fabricated substation is for HV/LV equipment,transformer combination of a compactly equipment device.Widely used in urban high-rise buildings,urban and rural construction,residential areas,factories,parks,airports,railway,oil field,shopping malls and
temporary construction and other outdoor venues.For receiving anddistribution of electric energy in power distribution system.
· Use condition
Altitude:≤2000m
Ambient temperature:-35ºC~+40ºC
Relative humidity:
Daily average≤95%
Monthly average≤90%
Seismic capacity:8 degrees
Current | AC |
Altitude | ≤2000m |
Ambienttemperature | -35ºC-+40ºC |
Seismic Capacity | 8 degree |
· Structure characteristic
1. Substation shell adopts the surface treatment of steel manufacturing,has enough mechanical strength and rigidity.
2. The shell material is made of cold rolled steel plate,stainless steel plate,aluminum alloy plate,after choi plate,etc
3. Each chamber is use the steel plate into separate little room,the Layout is designed to ''or '' shape based on electricity demand.
4. To convenience to monitoring and maintenance,transformer room,high and low voltage room is equipped with lighting device.
5. The top plate with double-layer structure,to prevent thermal radiation increase indoor temperature.
6. Transformer is with natural ventilation,when the transformer room temperature more than setted temperature,the top of the axial flow fan antomatically start to control the temperature of the transformer room.
7 The connection parts equipped with sealing device,has the good moistureproof function.
Perfect protection performance,convenient operation,ensure the Safety of maintenance;
Note: Due to continuous product improvement, the dimensions provided in this sample are for reference only. If necessary, our company can design and produce according to user requirements. Please contact the company in time.
1. TECHNICAL SPECIFICATION
Item | Unit | Parameter | |
Rated voltage | KV | 12/0.4 | 24/0.4 |
Rated short-time power frequency withstand voltage(phase/fracture) | KV/1 min | 42/48 | 42/48 |
Rated lighting impulse withstand voltage(phase/ground) | KW | 75/85 | 75/85 |
Rated frequency | Hz | 50 | 50 |
Rated total loss | KW | 7.01 | 7.01 |
Rated maximum capacity | A | 630 | 630 |
Ground circuit short time withstand current and duration | KA/S | 20/0.5s | 20/0.5s |
Rated peak withstand current | KA | 50 | 50 |
Enclosure rating | IP30 | IP33D | |
Rated housing rating | 10 | 10 |
· Ordering instruction
2. Model, specification and quantity of main components.
3. Incoming and outgoing line mode and cable specification, etc.
4. Shell material and appearance: composite plate, steel plate, stainless steel plate, cement plate, etc.
5. Other order requirements.
Enter Your Message