Product Details:
|
|
Place of Origin: | China |
---|---|
Brand Name: | HENGFENGYOU |
Certification: | ISO IEC CB COC KEMA SNI SABS CCC |
Model Number: | XGN |
Payment & Shipping Terms:
|
|
Minimum Order Quantity: | 1 |
Price: | 200-20000/piece |
Packaging Details: | wooden case |
Delivery Time: | 30 days |
Payment Terms: | LC T/T |
Supply Ability: | 5000 piece/year |
Detail Information |
|||
Model Number: | XGN | Type: | Metal Clad, Box Type Fixed Withdrawable Switchgear |
---|---|---|---|
Rated Frequency: | AC 50Hz (60Hz) | Rated Current(A): | 630, 1250, 1600, 2500, 3510, 4000 |
Customized: | OEM/ODM Order Acceptable | Application: | Power Transmission Or Distribution |
Product Name: | Electrical Kyn28 12 Switchgear 11kv | Rated Voltage: | 3KV, 7.2KV, 12KV Optional |
Comply Standards: | DL/T404, IEC298,GB3906 | ||
High Light: | mv switchgear panel,medium voltage cabinet |
Product Description
XGN15-12 Medium Voltage Switchgear
Xgn15-12 ac high voltage sulfur hexafluoride ring network switching equipment (hereinafter referred to as the ring network cabinet) is widely used in industrial and mining enterprises, high-rise buildings, residential communities, schools, etc., as 10KV power distribution system ring network power supply and terminal distribution.
Structural Features
Xgn15-12 type combined sulfur hexafluoride ac metal closed-loop switchgear is a new generation of metal closed switchgear with sulfur hexafluoride switch as the main switch, air insulation, compact structure, expandable.It is characterized by simple structure, flexible operation, reliable interlock and convenient installation.It has different applications.According to the requirements of different users to provide satisfactory technical solutions.
The adoption of sensor technology and protective relays, coupled with advanced technical performance and portable and flexible assembly solutions, can meet the changing needs of the market.
Xgn15-12 unit sulfur hexafluoride ring cabinet is suitable for 50hz, 12kv ac power system, widely used in industrial and civil cable ring network and power supply terminal engineering.Especially suitable for the following places: special places requiring automatic switching of double power supply, urban residential distribution network, small secondary substation, open and close houses, industrial and mining enterprises, shopping malls, airports, subway, wind power, hospitals, stadiums, railways, tunnels, etc.
Protection level up to IP2X.
Main technical parameters | ||
Main circuit rated voltage(V) | .......................... | Ac 400 (600) |
Rated voltage of auxiliary circuit (V) | .......................... | Ac 220/380 (400) dc 110/220 |
Rated frequency (Hz) | .......................... | 50(60) |
Rated insulation voltage(V) | .......................... | 690(1000) |
Rated current(A) | The level of bus | ≤6000 |
Rated short-time bus withstand current (kA/1s) | .......................... | 50,80 |
Rated peak withstand current of bus (kA/0.1s) | .......................... | 105,176 |
Power frequency test voltage (V/1min) |
main circuit | 2500 |
Auxiliary circuit | 1760 | |
bus |
Three-phase four-wire system | A,B,C,PEN |
Three-phase five-wire system | A,B,C,PE,N | |
Protection grade | .......................... | IP30 |
Rated isolation voltage | To 1000V |
Rated operational voltage | To 600V |
Rated frequency | 50 /60 Hz |
Rated impact withstand voltage | 8 kV |
Rated voltage of auxiliary circuit | AC380, 220V,DC 220V |
Over voltage degree | III |
Pollution degree | 3 |
Rated current | 4000A |
Horizontal busbar rated current | 4000A |
Vertival busbar rated current |
2000, 1000A |
Note: Due to continuous product improvement, the dimensions provided in this sample are for reference only. If necessary, our company can design and produce according to user requirements. Please contact the company in time.
Conditions of Use
Elevation: the elevation shall not exceed 2000MM;
Ambient temperature: -25°C~40C;
Relative humidity: daily average is no more than 95%, and monthly average is no more than 90%;
Surrounding environment: the surrounding air is not polluted by corrosive gases or flammable gases, water vapor, etc.No frequent violent vibration.
If the above normal conditions of use are exceeded, the user may negotiate with the company.
Enter Your Message