China Electrical Power Transformer manufacturer

Indoor Metal Clad Medium Voltage Switchgear For Power Transmission / Distribution

Product Details:
Place of Origin: China
Brand Name: HENGFENGYOU
Certification: ISO IEC CB COC KEMA SNI SABS CCC
Model Number: KYN28
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: 200-20000/piece
Packaging Details: wooden case
Delivery Time: 30 days
Payment Terms: LC T/T
Supply Ability: 5000 piece/year
Contact Now

Detail Information

Model Number: KYN28A-12 Type: Metal Clad
Rated Frequency: AC 50Hz (60Hz) Rated Current(A): 630, 1250, 1600, 2500, 3510, 4000
Customized: OEM/ODM Order Acceptable Application: Power Transmission Or Distribution
Product Name: Electrical Kyn28 12 Switchgear 11kv Rated Voltage: 3KV, 7.2KV, 12KV Optional
Comply Standards: DL/T404, IEC298,GB3906 Standard: IEC298/GB3906
Certification: Test Report, CE, CCC, ISO9001
High Light:

medium voltage distribution panel

,

medium voltage cabinet

Product Description

MV medium voltage KYN28-12 metal-clad switchgear

 

KYN28 indoor metal-clad withdrawable switchgear(hereinafter short as switchgear) which is for distributing and accepting 3-phase AC electricity (3-12 kV, 50 Hz) distribution system, single-bus and single-bus sectionalized system. It is universally applied within power transmission of middle/small generators in power plants; power receiving, transmission for substations in power distribution and power system of factories, mines and enterprises, and starting of large high-voltage motor, etc. The switchgear compliant with IEC298,GB3906-9. Besides, it also can control, protect and monitor the circuit.
Simple and effective lock system to prevent misuse. Reliable FIVE-PREVENTION interlock can effectively prevent from mal-operation and entrance into energized compartments.
1, Prevent pushing and pulling circuit breaker handcart with loads;

2, Prevent circuit breakers from mal-operation;

3, Prevent the circuit breaker from closing and connecting when earth switch in live condition;

4, Prevent straying into electrified compartment;

5, prevent connecting error of grounding switch while live.
Perfect Removable part of the switchgear can mount with vacuum circuit breaker and vacuum contactors components, etc.
The cabinet can debugged or maintained from front or behind, when adopt front side for debugged,
can be installed against a wall or back-to-back be a double arrangement, more flexible for installation and reducing floor space.

Indoor Metal Clad Medium Voltage Switchgear For Power Transmission / Distribution 0

 
Item Unit Parameters
Rated voltage KV 3, 7.2, 12
Rated current A 630,1250,1600,2500,3150,4000*
Rated short circuit breaking current KA 25, 31.5, 40
Rated short circuit switching current 63, 80, 100
Rated short-yime withstand current(4s) 25, 31.5, 40
Rated peak withstand current 63, 80, 100
Rated frequency Hz 50
Rated insulation level 1 min power frequency withstand voltage KV 42
Lighting impulse withstand voltage 75
control circuit voltages AC V 110, 220, 380
DC V 110, 220
Protection degree   Housing IP4X , cubicle and circuit breaker IP2X when door is open