China Electrical Power Transformer manufacturer

11KV 12KV 15KV 20KV 22KV 24KV 33KV 35KV 36KV High Voltage Metal Enclosed SF6 Gas Insulated Ring Main Unit RMU Switchgear

Product Details:
Place of Origin: China
Brand Name: HENGFENGYOU
Certification: ISO IEC CB COC KEMA SNI SABS CCC
Model Number: SF6
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: 200-20000/piece
Packaging Details: wooden case
Delivery Time: 30 days
Payment Terms: LC T/T
Supply Ability: 5000 piece/year
Contact Now

Detail Information

Model Number: SF6 Type: Metal Clad
Rated Frequency: AC 50Hz (60Hz) Rated Current(A): 630, 1250, 1600, 2500, 3510, 4000
Customized: OEM/ODM Order Acceptable Application: Power Transmission Or Distribution
Product Name: Electrical Kyn28 12 Switchgear 11kv Rated Voltage: 3KV, 7.2KV, 12KV Optional
Comply Standards: DL/T404, IEC298,GB3906
High Light:

switchgear control panel

,

metal clad switchgear

Product Description

Electric High Voltage Single SF6 gas insulated RMU switchgear

 

Feature:

Use SF6 load switch and load switch-fuse combination as main switch. Equipped with vacuum load switch and spring operating mechanism which can be operated by hand or electric. Earthing switch and insulating switch are equipped with hand operating mechanism. With small volume and high security

 

1.Many years ring mian unit manufacturer
2.Easy installation
3.Less maintance
4.Safe and upgradeable

 

Standard:

NATIONAL STANDARD: GB11022
GB3906
GB1984
GB3804
GB16926

 

INTERNATIONAL STANDARD: IEC60376
IEC60298
IEC60420
IEC60282
DIN VDE0670
IEC60129
IEC60265-1
IEC60694
IEC60056

 

11KV 12KV 15KV 20KV 22KV 24KV 33KV 35KV 36KV High Voltage Metal Enclosed SF6 Gas Insulated Ring Main Unit RMU Switchgear 0

Service conditions

 

◎ Ambient air temperature: -15°C〜+40°C;

◎ Relative humidity: Daily average ≤ 95%,and daily average of water vapor pressure < 2.2kPa;

Monthly average ≤ 90%,and monthly average of water vapor pressure < 1.8kPa;

◎ Altitude: ^ 1000m;

◎ Seismic intensity: No more than 8 degree

◎ Ambient air should be free of pollution of corrosive or flammable gas or vapor;

◎ No obvious vibration;

 

Note: Due to continuous product improvement, the dimensions provided in this sample are for reference only. If necessary, our company can design and produce according to user requirements. Please contact the company in time.

 

Item Unit Parameters
Rated voltage KV 3, 7.2, 12
Rated current A 630,1250,1600,2500,3150,4000*
Rated short circuit breaking current KA 25, 31.5, 40
Rated short circuit switching current 63, 80, 100
Rated short-yime withstand current(4s) 25, 31.5, 40
Rated peak withstand current 63, 80, 100
Rated frequency Hz 50
Rated insulation level 1 min power frequency withstand voltage KV 42
Lighting impulse withstand voltage 75
control circuit voltages AC V 110, 220, 380
DC V 110, 220
Protection degree   Housing IP4X , cubicle and circuit breaker IP2X when door is open

 

 

Main technical parameters
Main circuit rated voltage(V) .......................... Ac 400 (600)
Rated voltage of auxiliary circuit (V) .......................... Ac 220/380 (400) dc 110/220
Rated frequency (Hz) .......................... 50(60)
Rated insulation voltage(V) .......................... 690(1000)
Rated current(A) The level of bus ≤6000
Rated short-time bus withstand current (kA/1s) .......................... 50,80
Rated peak withstand current of bus (kA/0.1s) .......................... 105,176

 

Power frequency test voltage (V/1min)

main circuit 2500
Auxiliary circuit 1760

 

bus

Three-phase four-wire system A,B,C,PEN
Three-phase five-wire system A,B,C,PE,N
Protection grade .......................... IP30

 

 

11KV 12KV 15KV 20KV 22KV 24KV 33KV 35KV 36KV High Voltage Metal Enclosed SF6 Gas Insulated Ring Main Unit RMU Switchgear 1

 

11KV 12KV 15KV 20KV 22KV 24KV 33KV 35KV 36KV High Voltage Metal Enclosed SF6 Gas Insulated Ring Main Unit RMU Switchgear 2

 

 

 

 

 

 

 

 