Product Details:
|
|
Place of Origin: | China |
---|---|
Brand Name: | HENGFENGYOU |
Certification: | IEC CB COC KEMA SNI SABS CCC |
Model Number: | ZW32-12 Zw32-12f /630 |
Payment & Shipping Terms:
|
|
Minimum Order Quantity: | 1 |
Price: | 200-5000/piece |
Packaging Details: | wood |
Delivery Time: | 15 days |
Payment Terms: | T/T |
Supply Ability: | 20000 pieces/year |
Detail Information |
|||
Poles Number: | 3 | Type: | Vacuum |
---|---|---|---|
Rated Voltage: | 12KV | Rated Current: | 630A |
Product Name: | High Voltege 12kv Vacuum Circuit Breaker With Overload Protector | Application: | Circuit-breaking |
Keywords: | Circuit Breakers | ||
High Light: | vcb circuit breaker,vacuum circuit switch |
Product Description
Zw32-40.5 high voltage vacuum circuit breaker 35kv
ZW32-12 outdoor high voltage AC vacuum circuit breaker is a three-phase AC outdoor high voltage power distribution
Product Details
Zw32-40.5 vacuum switch is an outdoor switchgear with rated voltage of 40.5kv and three-phase ac of 50Hz.2. Power: it is mainly used for the load current, overload current and short-circuit current in the power system.It is suitable for protection and control in urban and rural power grid, and more suitable for frequent operation.3. Special point: the structure of the outdoor fixed sealing pole column is novel: the unique squirrel cage frame structure enables the inner blanking layer and the outer umbrella skirt to be formed by an automatic pressure injection of silicone rubber, and the original manual operation method is replaced by the mechanical control method to avoid the breakdown fault of the fracture insulation.External current transformer;The external operating mechanism can reduce the weight of the circuit breaker body, facilitate the assembly and debugging of the production process, and facilitate the operation, maintenance and maintenance after operation.(1) ambient temperature: the upper limit is +40℃, and the lower limit is -40 ℃;(2) elevation: not higher than 1000 meters;(3) relative humidity: the daily average is no more than 95%, and the monthly average is no more than 90%.
Note: Due to continuous product improvement, the dimensions provided in this sample are for reference only. If necessary, our company can design and produce according to user requirements. Please contact the company in time.
No. | Item | Unit | Data |
1 | Rated voltage | kV | 12 |
2 | Rated frequency | Hz | 50 |
3 | Rated current | A | 630,1250 |
4 | Rated short circuit breaking current | kA | 12.5,16,20,25 |
5 | Rated peak withstand current | kA | 31.5,40,50,63 |
6 | Rated short time tolerance current(4s) | kA | 12.5,16,20,25 |
7 | Rated short circuit opening and closing current | kA | 31.5,40,50,63 |
8 | Institution life | time | 10000 |
9 | Rated short open circuit current switch frequency | time | 30 |
10 | Rated current open circuit frequency | time | 10000 |
11 | Power frequency withstand voltage (1min) : phase, ground/fracture | kV | 42/48 |
12 | Lightning shock withstand pressure(peak)phase, ground/fracture | kV | 75/85 |
13 | Power frequency withstand voltage of the secondary circuit )(1min) | kV | 2 |
14 | Net weight | kg | 140 |
Conditions of Use
When ordering, the customer should provide the following information:
1. Main loop scheme diagram and -secondary system diagram.
2. Auxiliary circuit electrical schematic diagram and terminal arrangement diagram, if there is no schematic diagram and terminal arrangement diagram, according to the manufacturer's standard.
3. Equipment arrangement and combination drawing and plane layout drawing.
4. Model, specification and quantity of main electrical components in the equipment.
5. Incoming and outgoing wire method and cable specification. If bus connection is needed between the equipment or the incoming wire unit, bus span, height from the ground and other data shall be provided.
6. Surface color of equipment.
7. Negotiate with the manufacturer for other special requirements.
· Order instructions:
1. The customer needs provide main parameters of the transformer (input and output voltage, capacity, loss, etc.)
2. Other customer requirements