Product Details:
|
|
Place of Origin: | China |
---|---|
Brand Name: | HENGFENGYOU |
Certification: | ISO IEC CB COC KEMA SNI SABS CCC |
Model Number: | SCB10 |
Payment & Shipping Terms:
|
|
Minimum Order Quantity: | 1 |
Price: | 200-200000/piece |
Packaging Details: | wooden case |
Delivery Time: | 15 DAYS |
Payment Terms: | LC T/T |
Supply Ability: | 5000 pieces/year |
Detail Information |
|||
Material: | Aluminum Or Copper | Usage: | Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer |
---|---|---|---|
Capacity: | 100.125.160.200.250.315.400.500.630.800.1000 | HS Code: | 85043190 |
Product Name: | Dry Type Transformer | Certificate: | CE,ISO,CQC,SABS,3C |
High Light: | cast resin dry type transformer,dry cast resin transformers |
Product Description
Product introduction
Compared with model scb12 epoxy resin cast three-phase dry-type transformer, model scb13 dry-type transformer is a new upgrading generation product. Its no-load loss reduces by 5% compared with model scb12, showing significant energy-saving effect. Meanwhile, it is safe, fire-retardant, pollution-free, maintenance free and easy installation. With good moisture-proof performance, it can restart without pre-drying after shutdown. This model shows low loss, low partial discharge and low noise. Under forced air cooling, it can operate at 120% of rated load. Perfect temperature protection and control system provides reliable guarantee for the safe operation of the transformer.
Application
SC(B) Series DRY EPOXY RESIN DISTRIBUTION POWER TRANSFORMER is widely applied in hotels, high buildings, business centers, residence community, gymnasium, Petrochemical plant, airport, harbor, metro, mine, drillic.
Technical data
Rated capacity(kVA) | H.V. winding | Tapping | L.V. winding | Vector Group | No-load loss (kW) | Load loss (kW) | No-load current (%) | short circuit impedance |
30 50 80 100 125 160 200 250 315 400 500 630 630 800 1000 1250 1600 2000 2500 | 6 6.6 6.6 10 10.5 11 | ±5% ±2x2.5% | 0.4 | Dyn11 | 0.13 0.19 0.26 0.28 0.33 0.38 0.44 0.51 0.62 0.69 0.81 0.94 0.91 1.07 1.24 1.46 1.72 2.14 2.52 | 0.71 1.00 1.38 1.57 1.85 2.13 2.53 2.76 3.47 3.99 4.88 5.88 5.96 6.96 8.13 9.69 11.73 14.45 17.17 | 2.6 2.2 2.2 2 1.8 1.8 1.6 1.6 1.4 1.4 1.4 1.2 1.2 1.2 1.1 1.1 1.1 1.0 1.0 | 4 4 4 4 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 |
·Structural features
1. Low partial discharge:
Adoption of leading mixing method and the membrane-type vacuum deaerator makes the mixture material evenly and eliminates the bubbles at the bottom of the mixture. The product demonstrates low partial discharge and can be controlled at 5pc. Both high voltage coil and the low voltage coil can be casted under vacuum pressure, which generates encapsulation of resin insulation with characteristics of flame retardant, explosion-proof and environment protection.
2. Raw materials of winding coil such as glass fiber have self-extinguishing property, which will not produce arc when short circuit. The resin will not produce harmful gases at high temperature.
3. High mechanical strength: the resin with filler produces small difference of expansion coefficient in the casting body, small curing shrinkage rate, small internal stress, and high hardness of the solidified object. In the epoxy resin coating on the inner and outer surfaces of the high and low pressure coils, there are preformed reinforced materials, which have similar dense structure as the reinforced concrete, so mechanical strength of the casting body of this technique is greater than pure epoxy resin, and can withstand electrodynamic action under sudden short-circuit meanwhile without damage .
4. Low loss and energy-saving: The adoption of isotropic soft magnetic material generates low magnetization power, high electrical resistivity and low eddy current consumption.
1.working condition
* Device types: indoor type
* Normal environment conditions of use: the elevation not more than 1000 m
* Environmental highest temperature + 40℃, minimum-25 ℃
* The special environment conditions of use: elevation of more than 1000 m
* Environmental highest temperature + 40 ℃, minimum-45 ℃. (when you order details)
* Mounting ambicnt: no corrosive gas, no obvious dirt environment
2.applicable standard
* IEC60076 power transformer
* IEC723 dry power transformer
* GB6450-1986 dry power transformer
* GB/R1094-1996 power transformer
* GB4208-1993 outer shell protect grade(IP code)
All products of the company have passed the national type test like CCC, CQC , CTQC and other
national mandatory product certification, and has a perfect quality, occupational health and
environmental management system certification system. Our products have passed ISO9001, 2000
and other international quality system certification.
None of the dry-type transformers we see today are installed in a separate, tightly enclosed room, as in
the oil-immersed type, but only in a relatively dry and clean room. In addition to this, it is also very convenient
to transport or carry, no matter what kind of transport vehicles, trains, cars or other non-motor vehicles can be,
but it is best to keep the car dry, clean and the product itself in good packaging. Practice has proved that really
good products will always be more and more marketable. As dry-type transformers have very good fire-proof
performance and are easy to install and maintain, they are also used more and more widely Especially in the
modern commercial downtown, residential areas, hospitals, airports, stations, subways, theaters, schools,
public places and other places with high requirements on fire protection.
Enter Your Message