China Electrical Power Transformer manufacturer

Cast Resin Dry Type Transformers Cast Coil Power Electrical Transformers For Nuclear Plants

Product Details:
Place of Origin: China
Brand Name: HENGFENGYOU
Certification: ISO IEC CB COC KEMA SNI SABS CCC
Model Number: SCB10,11,12,13
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: 200-200000/piece
Packaging Details: wood pack
Delivery Time: 15 DAYS
Payment Terms: T/T
Supply Ability: 5000 pieces/year
Contact Now

Detail Information

Usage: Power Distribution Transformer Coil Number: Autotransformer,double Winding
Phase: Three,Single Frequency: 50/60Hz
Type: Dry Type Transformer,Cast Resin Product Name: 3 Phase Dry Type Electrical Transformer 300kva,Dry Type 10kva 440v To 220v Three Phase Transformer
Material: Copper,amorphmos Alloy Input Voltage: 11kv/10.5kv/10kv/6.3kv/6kv

Product Description

Cast Resin Dry Type Transformers Cast Coil Power Electrical Transformers For Nuclear Plants

 

·Product introduction

 

 

The series of epoxy cast dry-type transformers value high-quality materials, formulation science,

advanced manufacturing and testing equipment is made according to strict production process. Products with high reliability and long life characteristics. Depending on the use of the environment, can be configured to different levels of protection or do not configure the shell casing. For high-rise buildings, commercial centers, airports, tunnels, chemical plants, nuclear power plants, ships and other important places or special environment.

 

Cast Resin Dry Type Transformers Cast Coil Power Electrical Transformers For Nuclear Plants 0

·Structural features

1. Security, fire, pollution-free, can be run directly on the load center.

2. HTT using German technology, high mechanical strength, resistance to short-circuit capability, partial discharge, thermal stability, high reliability and life of plants.

3. Low loss, low noise, energy-saving effect, maintenance-free.

4. Thermal performance, overload capability, forced air cooling can increase the capacity to run.

5. Moisture resistant, and adapt to high humidity and other harsh environments.

6. Can be equipped with temperature monitoring and improve the protection system.

7. Temperature control system using intelligent signal, automatically monitor and display three-phase winding road of their operating temperature, can automatically start and stop the fan, and has an alarm, trip and other functions set.

7. Small size, light weight, small footprint, low cost of installation.

8. High quality cold-rolled silicon steel core, 45-degree miter joints ladder structure, the use of three core cut to the corner two red and five cross-cutting process step ladder and stacked cut sheet iron craft, improved the seams of the flux distribution, reducing the core of the vibrational energy.

9. One core to the surface with insulating resin curing and sealing process, effectively reducing the load loss, load flow and core noise.

10. High voltage coil insulation class F high-quality wire and advanced insulation materials around the system, with a larger capacity cooling coil along the axial airway.

11. This structure has good resistance to current impact, temperature resistant, anti-cracking and excellent heat dissipation.

12. Multi-level sub-cylindrical structure, strong ability to withstand over-voltage and low partial discharge level.

13. Coil fitted after the casting mold by vacuum drying, the whole process of casting and curing process in accordance with pre-programmed to complete the curve, precise process control to ensure that the coil no holes, holes.

14. Foil using low-voltage coil structure, effectively low-voltage, high current coil ampere-turns using wire-wound type of imbalance, but there is no axial foil coil winding turns and axial spiral angle, effectively eliminating transformer short-circuit axial force to ensure that the coil current density within the high voltage ring load can be distributed freely along the axial adjustment to reduce the sudden short-circuit when the low radial force.

15. After winding the coil end of the curing resin seal, to avoid the entry of foreign matter and moisture.

 

·Service conditions

1. The maximum ambient air temperature shall not exceed 40 ℃, and the minimum shall be not below - 15 ℃;

2. The altitude shall not exceed 1000m. If special customized transformers and low-voltage components are used, the altitude can reach 4000m;

3. The vertical inclination is no more than 5 °, and no violent vibration and impact;

4. The air humidity is not more than 90% (+ 25 ℃);

5. Places without gas and conductive dust that will seriously affect the insulation of transformer, no explosion hazard and corrosion of electrical components;

6. Outdoor wind speed shall not exceed 35m / s.

7. If service conditions exceed the above, specially customized product is available with our company through mutual communication.

 

Cast Resin Dry Type Transformers Cast Coil Power Electrical Transformers For Nuclear Plants 1


10/0.4kV Dry Type transformer Technical parameters(Second level of energy efficiency)

Rated
capacity
(kVA)
Voltage combination Connected
group label
No-load
loss (W)
Load loss(W) No-load
current(%)
Impendace
voltage (%)
sound
power
level (dB)
Exterior size
(L x w x h)
Total
weight
(kg)
High
voltage(kV)
tap
range
Low
Voltage (kV)
130°C(B) 155°C(F) 180°C(H)
100°C 120°C 145°C
30 6
6.3
6.6
10
10.5
11
±2 x 2.5

±5
0.4 Dyn11 150 670 710 760 0.6 4.0 57 900 x 900 x 800 300
50 215 940 1000 1070 0.6 955 x 900 x 900 350
80 295 1290 1380 1480 0.6 58 985 x 950 x 960 400
100 320 1480 1570 1690 0.6 1035x1250x980 450
125 375 1740 1850 1980 0.6 59 1060x1280x1000 500
160 430 2000 2130 2280 0.6 1120x1320x1050 680
200 495 2370 2530 2710 0.5 60 1135x1330x1105 770
250 575 2590 2760 2960 0.5 1170x1330x1165 900
315 705 3270 3470 3730 0.5 62 1185x1360x1225 1010
400 785 3750 3990 4280 0.4 1210x1380x1300 1205
500 930 4590 4880 5230 0.4 63 1245x1400x1380 1400
630 1070 5530 5880 6290 0.4 63 1295x1410x1355 1515
1040 5610 5960 6400 0.3 6.0 63 1295x1410x1355 1515
800 1210 6550 6960 7460 0.3 65 1375x1450x1480 1880
1000 1410 7650 8130 8760 0.3 1430x1480x1525 2170
1250 1670 9100 9690 10300 0.25 67 1480x1500x1570 2525
1600 1960 11000 11700 12500 0.25 1500x1520x1710 2980
2000 2440 13600 14400 15500 0.20 69 1570x1550x1735 3480
2500 2880 16100 17100 18400 0.20 1625x1600x1825 4080
1600 1960 12200 12900 13900 0.25 8.0 67 1500x1520x1710 2980
2000 2440 15000 15900 17100 0.20 69 1570x1550x1735 3480
2500 2880 17700 18800 20200 0.20 1625x1600x1825 4080


Note: due to the constantly updated products, shape size and product weight in the table will have some changes, please refer to provide the appearance size chart when ordering.
 

·Order instructions:

1. The customer needs provide main parameters of the transformer (input and output voltage, capacity, loss, etc.)

2. Other customer requirements

 

 

Cast Resin Dry Type Transformers Cast Coil Power Electrical Transformers For Nuclear Plants 2

 

 

 

Get in touch with us

Enter Your Message

You Might Be Into These