Product Details:
|
|
Place of Origin: | China |
---|---|
Brand Name: | HENGFENGYOU |
Certification: | ISO IEC CB COC KEMA SNI SABS CCC |
Model Number: | ks9 |
Payment & Shipping Terms:
|
|
Minimum Order Quantity: | 1 |
Price: | 200-200000/piece |
Packaging Details: | wooden case |
Delivery Time: | 15 DAYS |
Payment Terms: | LC T/T |
Supply Ability: | 5000 pieces/year |
Detail Information |
|||
Usage: | Power | Product Name: | Three Phase Oil Transformer |
---|---|---|---|
Frequency: | 50Hz/60Hz | Output Voltage: | Customize |
Color: | Optional | Application: | Change Voltage |
Place Of Origin: | Qingdao,China | ||
High Light: | oil immersed distribution transformer,oil immersed power transformer |
Product Description
oil-immersed transformer S9,30-2500KVA,6.9KV series,3 phase/fully sealed/double winding
Product Features:
This product is suitable for power supply and distribution in coal mine, iron mine, aluminum mine, copper mine, gold mine, silver mine, zinc mine, titanium mine, oil field, gas field, oil and gas station,explosion hazard gas etc.
Technical data
Type |
Rated Capacit(kVA)
|
H.V. winding (kV)
|
Tapping range of high voltage(%)
|
L.V. winding (kV) |
Vector Group |
No-load Loss(W) |
Load Loss (W) |
No-load current (%) |
Short-circuit impedance (%) |
ks9-200/6 | 200 | 6 | ±5 |
0.693 0.4 |
y,d11-d,d0 or y,y0,d11 |
0.48 | 2.600 | 1.3 |
4 4.5 |
ks9-250/6 | 250 | 0.56 | 3.050 | 1.2 | |||||
ks9-315/6 | 315 | 0.67 | 3.650 | 1.1 | |||||
ks9-400/6 | 400 | 0.80 | 4.300 | 1.0 | |||||
ks9-500/6 | 500 | 096 | 5.100 | ||||||
ks9-630/6 | 630 | 1.20 | 6.200 | 0.9 |
Structural characteristics
The configuration structure is shield type, winding number is double winding, iron core structure is shell type, power supply phase number is three phase, iron core shape is E type, the processing is customized type, the cooling form is oil-immersed, frequency characteristic is medium frequency, the application range is mine, moisture-proof way is sealed.
Material
Oxygen-free copper lines of lower resistivity, which will become smoother and burr-free after series of additional surface treatment, so the load loss of our transformer is lower and the electric performance is better.
High-quality silicon-steel plates which are of lower unit loss, and the no-load of the transformers is lower.
High-quality wooden laminating insulation pieces, which won’t split or move even under the influence of short circuit.
Thoroughly filtrated transformer oil containing less water, gas and impurities, which makes our transformers work better.
High-quality rubber sealing material, which can prevent the transformers form aging or leakage.
Workshop
·Service conditions
1. The maximum ambient air temperature shall not exceed 40 ℃, and the minimum shall not below - 25 ℃;
2. The altitude shall not exceed 1000m. If special customized transformers and low-voltage components are used, the altitude can reach 4000m;
3. The vertical inclination is no more than 5 °, and no violent vibration and impact;
4. The air humidity is not more than 90% (+ 25 ℃);
5. No gas and conductive dust that will seriously affect the insulation of transformer, no explosion hazard and corrosion of electrical components;
6. Outdoor wind speed shall not exceed 35m / s.
7. If service conditions beyond the above, specially customized product is available.
If any interest , pls feel free to contact us:
Enter Your Message